Publications

Export 29 results:
Author Type [ Year(Asc)]
Filters: Author is Jan De Beenhouwer  [Clear All Filters]
2017
V. Van Nieuwenhove, J. De Beenhouwer, T. De Schryver, L. Van Hoorebeke, and J. Sijbers, "Data-Driven Affine Deformation Estimation and Correction in Cone Beam Computed Tomography", IEEE Transactions on Image Processing, vol. 26, issue 3, pp. 1441-1451, 2017.
E. Janssens, J. De Beenhouwer, J. Sanctorum, S. Senck, C. Heinzl, and J. Sijbers, "Dual axis Dark Field Contrast Tomography for visualisation of scattering directions in a CFRP sample", 4th Conference on X-ray and Neutron Phase Imaging with Gratings, Zürich, Switzerland, pp. 79-80, 09/2017. Download poster (729.94 KB) Download abstract (116.29 KB)
E. Janssens, S. Senck, C. Heinzl, J. Kastner, J. De Beenhouwer, and J. Sijbers, "Fast Reconstruction of CFRP X-ray Images based on a Neural Network Filtered Backprojection Approach", 7th Conference on Industrial Computed Tomography, Leuven, Belgium, 2017. Download paper (345.06 KB)
V. Van Nieuwenhove, J. De Beenhouwer, J. Vlassenbroeck, M. Brennan, and J. Sijbers, "MoVIT: A tomographic reconstruction framework for 4D-CT", Optics Express, vol. 25, issue 16, pp. 19236-19250, 2017.
V. Van Nieuwenhove, J. De Beenhouwer, J. Vlassenbroeck, M. Moesen, M. Brennan, and J. Sijbers, "Registration Based SIRT: A reconstruction algorithm for 4D CT", 7th Conference on Industrial Computed Tomography, Leuven, Belgium, 2017. Download paper (2.36 MB)
J. Sanctorum, E. Janssens, A J. den Dekker, S. Senck, C. Heinzl, J. De Beenhouwer, and J. Sijbers, "A workflow to reconstruct grating-based X-ray phase contrast CT images: application to CFRP samples", 4th Conference on X-ray and Neutron Phase Imaging with Gratings, Zürich, Switzerland, pp. 139-140, 09/2017. Download poster (665.27 KB) Download abstract (227.91 KB)
2016
W. Van Aarle, J. Cant, J. De Beenhouwer, and J. Sijbers, "Discrete tomographic reconstruction from deliberately motion blurred X-ray projections", 6th Conference on Industrial Computed Tomography, Wels, Austria, pp. 1-6, 2016. Download paper (444.66 KB)
V. Van Nieuwenhove, J. De Beenhouwer, and J. Sijbers, "Dynamic flat field correction in X-ray computed tomography", Optimess conference, Antwerp, 2016.
G. Van Eyndhoven, J. De Beenhouwer, and J. Sijbers, "A dynamic region estimation method for cerebral perfusion CT", 6th International Conference on Optical Measurement Techniques for Structures and Systems (OPTIMESS), pp. 331-342, 2016.
W. Van Aarle, W J. Palenstijn, J. Cant, E. Janssens, F. Bleichrodt, A. Dabravolski, J. De Beenhouwer, K. J. Batenburg, and J. Sijbers, "Fast and Flexible X-ray Tomography Using the ASTRA Toolbox", Optics Express, vol. 24, no. 22, pp. 25129-25147, 2016.
E. Janssens, L. F. Alves Pereira, J. De Beenhouwer, I R. Tsang, M. Van Dael, P. Verboven, B. Nicolai, and J. Sijbers, "Fast inline inspection by neural network based filtered backprojection: Application to apple inspection", Case Studies in Nondestructive Testing and Evaluation, vol. 6, pp. 14–20, 2016.
B. Goris, J. De Beenhouwer, A. De Backer, D. Zanaga, K. J. Batenburg, A. Sánchez-Iglesias, L. M. Liz-Marzán, S. Van Aert, J. Sijbers, G. Van Tendeloo, et al., "Investigating lattice strain in Au nanodecahedrons", European Microscopy Congress 2016, 2016.
K. Zarei Zefreh, J. De Beenhouwer, F M. Welford, and J. Sijbers, "Investigation on Effect of scintillator thickness on Afterglow in Indirect X-ray Detectors", 6th Conference on Industrial Computed Tomography, Wels, Austria (iCT 2016), 2016. Download paper (520.71 KB)
V. Van Nieuwenhove, G. Van Eyndhoven, K. J. Batenburg, N. Buls, J. Vandemeulebroucke, J. De Beenhouwer, and J. Sijbers, "Local Attenuation Curve Optimization (LACO) framework for high quality perfusion maps in low-dose cerebral perfusion CT", Medical Physics, vol. 43, issue 12, pp. 6429-6438, 2016.
A. Dabravolski, J. De Beenhouwer, and J. Sijbers, "Projection-based polygon estimation in X-ray computed tomography", 6th International Conference on Optical Measurement Techniques for Structures and Systems (OPTIMESS), pp. 41-50, 2016. Download paper (615.72 KB)
2015
V. Van Nieuwenhove, J. De Beenhouwer, T. De Schryver, L. Van Hoorebeke, and J. Sijbers, "Affine deformation correction in cone beam Computed Tomography", Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine, Newport, Rhode Island, USA, pp. 182-185, 2015. Download paper (2.91 MB)
W. Van Aarle, W J. Palenstijn, J. De Beenhouwer, T. Altantzis, S. Bals, K. J. Batenburg, and J. Sijbers, "The ASTRA Toolbox: a platform for advanced algorithm development in electron tomography", Ultramicroscopy, vol. 157, pp. 35–47, 2015. Download paper (1.4 MB)
V. Van Nieuwenhove, J. De Beenhouwer, F. De Carlo, L. Mancini, F. Marone, and J. Sijbers, "Dynamic intensity normalization using eigen flat fields in X-ray imaging", Optics Express, vol. 23, issue 21, pp. 27975-27989, 2015. Download Matlab code (2.92 MB) Download paper (22.81 MB)
V. Van Nieuwenhove, J. De Beenhouwer, and J. Sijbers, "A fast 4D CT reconstruction algorithm for affine deforming objects", Applied inverse problems conference, Helsinki, 2015.
E. Janssens, D. Pelt, J. De Beenhouwer, M. Van Dael, P. Verboven, B. Nicolai, and J. Sijbers, "Fast Neural Network Based X-Ray Tomography of Fruit on a Conveyor Belt", Chemical Engineering Transactions, vol. 44, Milano, Italy, pp. 181-186, 2015.
B. Goris, J. De Beenhouwer, A. De Backer, D. Zanaga, K. J. Batenburg, A. Sánchez-Iglesias, L. M. Liz-Marzán, S. Van Aert, S. Bals, J. Sijbers, et al., "Measuring Lattice Strain in Three Dimensions through Electron Microscopy", Nano Letters, vol. 15, issue 10, pp. 6996–7001, 2015.
E. Janssens, J. De Beenhouwer, M. Van Dael, P. Verboven, B. Nicolai, and J. Sijbers, "Neural Network Based X-Ray Tomography for Fast Inspection of Apples on a Conveyor Belt", IEEE International Conference on Image Processing, pp. 917-921, Sept 21-27, 2015.

Pages